Edged: ATL01-01 Data Center

Edged ATL01-01 Data Center is located at 1800 Thomas Street Northwest, Atlanta, GA 30318, USA. The data center is 208000 sqft. The gross colocation space is not available for this data center. It has access to 24.0 MW of power. We found 119 data center locations within 50 miles of this facility. No certifications are specified for this location.
Servers
Close
Bare Metal
Colocation Facility
Ok
Colocation
Technologies
Close
IaaS
Internet Exchange
Close
Internet Exchange
Details
Certifications
Media
Brochures
On Map

About ATL01-01 Data Center

Edged ATL01-01 (also referred to as ATL01-1) is a state-of-the-art data center facility operated by Edged Energy, located at 1800 Thomas Street NW, Atlanta, Georgia 30318, on the Edged Atlanta campus.Strategically positioned just ~5 miles from downtown Atlanta, the campus spans 80+ acres and offers 168 MW of critical IT capacity across its data center buildings.

This facility holds strong strategic significance as a high-density, AI-ready site designed for energy and water efficiency, supporting generative AI, cloud, and advanced computing workloads, while also leveraging Atlanta’s connectivity, pro-business environment, and access to major utility infrastructure. 

⚙️ Facility Highlights

  • Critical Capacity: ATL01-01 delivers 24 MW critical IT capacity. 
  • Campus Scale: Part of a larger Edged Atlanta campus which provides 168 MW total and sits on 80+ acres
  • Design PUE: Portfolio-average PUE (Power Usage Effectiveness) of 1.15
  • Cooling System: Advanced waterless cooling modular system. Uses a glycol heat transfer loop with rooftop air-cooled chillers; closed-loop evaporators for secondary cooling; hot aisle containment; flexible rack densities from ~70 kW (air cooling) up to 200 kW per rack with liquid cooling options. 
  • Power & Redundancy:
  • • Redundant utility feeds from Georgia Power. 
  • • Utility voltage transformation from 115 kV to 25 kV; internal delivery via busways (415/240 V) or 208/120 V. 
  • • UPS with static backup (≈ 1 MW) and N+1 redundancy; generators with N+1 redundancy and 24-hour fuel storage. 
  • Infrastructure & Build: Two-story, new-build structure; slab floor type; loading docks (two bays); office and storage space available; 24×7×365 access. 

🔐 Security & Compliance

  • Physical Security: Perimeter fencing; access gates. 
  • Internal Access Controls: Biometric readers; ID badges; man-traps; interior access segregation. 
  • Monitoring and Staffing: 24/7 manned onsite security; CCTV surveillance; real-time monitoring; full-time onsite support.
  • Certifications & Compliance: Fully compliant with industry standards for sustainability and efficiency; though no publicly confirmed third-party compliance (e.g. ISO, SOC) is explicitly listed for ATL01-01 in the sources found. (If you need those, I can try to pull up any that are documented elsewhere.)

🌐 Connectivity & Carrier Access

  • Carrier-Neutral Facility: Multiple carriers are supported; multiple fiber providers. 
  • Diverse Entry Points: Four diverse fiber entry points into the site’s telco duct banks. 
  • Meet-Me Rooms: Two meet-me rooms available within ATL01-01. 
  • High-Speed Fiber Connectivity: The campus is served by multiple high-speed fiber networks, supporting connectivity needed for cloud providers, AI workloads, etc. 

💼 Who It Serves

  • Companies deploying AI / ML / advanced computing workloads requiring high rack density and efficient cooling
  • Cloud service providers or hyperscale operators seeking sustainable infrastructure and high availability. 
  • Enterprises in industries with strong compliance, uptime, and reliability demands. 
  • Customers for whom energy efficiency, low environmental impact, and water conservation are priorities.

Contact Edged
Complete the form to get in direct contact with Edged.
Qty*
Colocation Space*
Select
Business Name*
Headquarters Address*
Contact Name*
Email*
*
Note (Optional)

Edged Locations in United States (9 Locations)

Edged
ATL01-01 Data Center
1800 Thomas Street Northwest, Atlanta, GA 30318, USA
Edged
ATL01-02 Data Center
1760 Thomas Street Northwest, Atlanta, GA 30318, EE. UU.
Edged
ATL01-03 Data Center
1740 Thomas Street Northwest, Atlanta, GA 30318, EE. UU.
Edged
Edged Chicago Data Center
2835 Bilter Road, Aurora, IL 60502, USA
Edged
Edged Columbus Data Center
6525 New Albany Road East, New Albany, OH, USA
Edged
Edged Dallas Data Center
505 N Wildwood Dr, Irving, Texas 75061, USA
Edged
Edged Kansas City Data Center
3420 North Arlington Avenue, Kansas City, MO 64161, USA
Edged
Edged Phoenix Data Center
8811 East Warner Road, Mesa, AZ 85212, USA
Edged
ORD01-2 Data Center
2835 Bilter Road, Aurora, IL 60502, EE. UU.