Element Critical: CH2 - Chicago Data Center

Facility Details341 Haynes Dr, Wood Dale, IL, USA
Phone
+1 866-396-4242
Building
50000 Sqfttotal space
Colocation
Not Availablecolocation space
Power
3.3 Mw total power
Products
0products
Airplane
3.11mi to the nearest airport

Element Critical: CH2 - Chicago Data Center

Element Critical CH2 - Chicago Data Center is located at 341 Haynes Dr, Wood Dale, IL, USA. The data center is 50000 sqft. The gross colocation space is not available for this data center. It has access to 3.3 MW of power. We found 89 data center locations within 50 miles of this facility. Certifications for this location include ISO 27001.

CHI2 is one of two neighboring data center facilities that is conveniently located near O’Hare International Airport which provides the power, connectivity and flexibility needed to customize unique solutions for specific IT objectives.  Acquired in 2018, the facilities were reconditioned to meet the growing demands of today’s enterprise user. 

CH2's specific power offerings include 2MW (available in both N+1 and 2N), backup power provide by 2 diesel generators with 8,000 gallon storage tank and a raised floor with all power and electrical distribution under raised floor.

Network
TIA-492 compliant, diverse fiber entrances, dedicated Meet-Me-Room, seven deployed providers, designed to add 12+ additional providers, dedicated dark fiber to key Internet exchanges
Fire Protection & Cooling
Dry-pipe fire suppression, pre-action and cooling total capacity of 1800 tons, N+1 unit redundancy and N+20% capacity redundancy
Security
ISO/IEC 27001: 2013 certification, 24X7X365 on-site staff, card access, 30-day CCTV video retention and multi-factor authentication required at all mission critical ingress locations
Backup Power
Three Cummins diesel generators, supporting 3MW of load, redundant fuel pumps and onsite fuel storage with dual, on-demand refueling contracts, redundant utility-to-generator transfer switches
Certifications
Close
HIPAA
Close
HITECH
Close
PCI-DSS
Close
ISAE-3402
Close
SSAE-16 Type 1
Close
SOC 2 Type 2
Ok
ISO 27001
Close
ISO 22301
Close
ISO 50001
Close
ISO 90001
Close
ISO 14001
Close
NIST Cloud
Close
FISMA
Close
DIACAP
Close
SOX
Close
FIPS-140
Close
EHNAC
Close
EU-US
Close
Privacy Shield
Close
SOC 1
Close
SOC 2
Close
SOC 3
Close
SOC 2 Type 1
Close
SSAE-16 Type 2
Close
FedRAMP
Close
SOC 1 Type 2
Close
NIST 800-53
Close
SSAE-18
Close
LEED
Facility Types
Ok
Internet Exchange
Ok
Cloud Node
Ok
Colocation Facility
Close
DRBC Site
Nearby Facilities89 Locations
Loading...
Element Critical
CH1 - Chicago Data Center
711 North Edgewood Avenue, Wood Dale, IL, USA