Goodman Group FRA02 is located at Frankfurt am Main, Germany. The gross building size for this location has not been provided. The gross colocation space is not available for this data center. No power information has been offered for this location. We found 199 data center locations within 50 miles of this facility. Certifications for this location include ISO 14001, ISO 27001, ISO 9001, PCI DSS.

About FRA02

FRA02 is a data centre development site published by Goodman as a “Data Centre” property in Neu Isenburg (Frankfurt Main region), Germany, with the site address listed as Rathenaustraße 29 31, 63263 Neu Isenburg.

Goodman describes FRA02 as the redevelopment of the former printing plant of the German newspaper Frankfurter Rundschau into a data centre campus south of Frankfurt, and positions the site as a powered shell intended for large operators (hyperscalers) and colocation data centre customers to complete their own fit out.

No facility level product catalogue (colocation services, bare metal, IaaS) is published by Goodman for FRA02 beyond the powered shell development positioning and technical site attributes. Not publicly disclosed.

⚙️ Facility Highlights

  1. Facility identity (operator stated): Goodman lists the site as FRA02 and classifies the property type as Data Centre.
  2. Address (operator stated): Goodman publishes the FRA02 address as Rathenaustraße 29 31, Frankfurt Main region Neu Isenburg, 63263 Neu Isenburg, Germany.
  3. Development context (operator stated): Redevelopment of the former Frankfurter Rundschau printing plant into a data centre south of Frankfurt.
  4. Campus IT power (operator stated): Goodman lists 54 MW IT campus and 54 MW IT power for FRA02.
  5. Utility capacity (operator stated): Goodman lists 100 MVA capacity for FRA02 and states 100 MVA power capacity secured.
  6. Site land area (operator stated): Goodman lists 50,000 sqm plot size.
  7. Location and latency positioning (operator stated): Goodman states FRA02 is less than 10 km from DE CIX (Hanauer Landstrasse) and about a 10 minute drive from Frankfurt airport.
  8. Connectivity positioning (operator stated): Goodman lists multi carrier connectivity, states a direct connection to fiber network is available at the plot, and references Tier 1 fibre carriers in close proximity (examples listed by Goodman include euNetworks, Colt, Gasline).
  9. Technical design statements (operator stated): Goodman lists Tier 3 compliant design, an on site high voltage substation (110kV to 20kV), and up to 100 MW redundant high voltage connection.
  10. Structural characteristics (operator stated): Goodman lists 2 tons floor load per sqm and clear height 5.8 m on the property page.
  11. Powered shell positioning (third party reporting): Industry reporting describes the project as a 100 MVA powered shell development in Neu Isenburg.

🔐 Security & Compliance

  1. CCTV surveillance (operator stated): Goodman lists CCTV surveillance on the FRA02 property page.
  2. Additional facility specific physical security systems (guards, mantraps, biometrics, access policies): Not publicly disclosed.
  3. Fire detection and suppression systems (facility specific): Not publicly disclosed.
  4. Compliance certifications (facility specific ISO SOC PCI, certificate IDs, audit scope): Not publicly disclosed.
  5. Sustainability certifications (operator stated, project level): Goodman states green building certification foreseen and that LEED platinum is targeted for FRA02.

🌐 Connectivity & Carrier Access

  1. Carrier neutral or carrier roster (facility specific): Not publicly disclosed.
  2. Connectivity positioning (operator stated): Goodman states multi carrier connectivity and that a direct connection to fiber network is available at the plot.
  3. Nearby network ecosystem references (operator stated): Goodman references proximity to Tier 1 fibre carriers (examples listed by Goodman include euNetworks, Colt, Gasline) but does not publish an on net carrier list for FRA02.
  4. Meet me room and cross connect products (facility specific): Not publicly disclosed.
  5. Internet Exchange (IX): Not publicly disclosed.
  6. PeeringDB facility record (third party directory): A PeeringDB facility record specifically for Goodman FRA02 was not located via public search. Not publicly listed.

💼 Who It Serves

  1. Hyperscalers and large operators (operator stated): Goodman positions FRA02 as suitable for the world’s largest operators and cloud providers and as a powered shell site intended for customer technical fit out.
  2. Colocation data centre customers (operator stated): Goodman states the site is ideal for co location data centre customers to install their technical fit out.
  3. Organizations prioritizing Frankfurt metro proximity (operator stated): The site is positioned for low latency access to DE CIX Frankfurt and the Frankfurt Rhein Main economic region.

NOTE: “under construction or scheduled to commence development by June 2026.”

Goodman Group Locations in Germany (1 Location)

View on Map