Linxdatacenter: Linx Moscow
Linxdatacenter Linx Moscow is located at улица 8 Марта, 14, строен.1, Москва, Russia. The gross building size for this location has not been provided. The gross colocation space is not available for this data center. It has access to 5.0 MW of power. We found 62 data center locations within 50 miles of this facility. No certifications are specified for this location.
IaaS
Internet Exchange
Colocation
About Linx Moscow
Linx Moscow Data Center is a commercial data center facility operated under the Linx brand in Moscow, Russia. Linx publishes the facility location as Moscow, ul. 8 Marta, 14, str. 1 on its official website (data centers section and company contacts).
A third-party interconnection directory (PeeringDB) publishes the facility record as “Linxdatacenter (Moscow)” with address 8 Marta 14 and facility notes including total area and total power.
⚙️ Facility Highlights
- Facility identity (third-party directory): Facility record name: “Linxdatacenter (Moscow)” (Organization: Linxdatacenter) in PeeringDB.
- Address (operator-stated): Moscow, ulitsa 8 Marta, d.14, str.1 (published on Linx “Наши дата-центры” section).
- Address (operator contacts / legal entity): Legal entity shown as ООО «Связь ВСД» with legal address 127083, Russia, Moscow, ul. 8 Marta, d.14, str.1; factual address listed as 127083, Russia, Moscow, ul. 8 Marta, d.14.
- Address (third-party directory): PeeringDB lists Address 1: 8 Marta 14 (Suite), Moscow, 127083, RU.
- Address (third-party mapping): Yandex Maps lists “Data center Linx Moscow” at 8 Marta Street, 14 (Moscow).
- Total area / size (operator-stated): Linx publishes 4,400 m² as the Moscow data center area on its “Наши дата-центры” section.
- Power (operator-stated): Linx publishes 5 MW for Linx Moscow on its “Наши дата-центры” section.
- Technical spec sheet (operator PDF): Linx Moscow technical PDF lists total area 4,400 m², design power 5 MW, and states the facility corresponds to TIER III.
- Power topology (operator PDF): Main power: 4 cable inlets from two independent electrical substations, redundancy 2N; backup power: UPS 2N and 9 diesel generator units (ДГУ).
- Cooling (operator PDF): Cooling described as dual-circuit using chillers, precision air conditioners, and free cooling, with redundancy 2N and N+1.
- Fire suppression (operator PDF): Automatic gas fire suppression Novec 1230 is listed.
- Connectivity (operator PDF): Connectivity notes include MSK-IX connection point and “more than 40” telecom operators.
🔐 Security & Compliance
- Facility-specific security systems (CCTV, mantraps, biometrics, guard force, access policies): Operator PDF lists video surveillance, physical security with regular patrols, and electronic pass-based access control, with optional additional customer security circuits.
- Facility-specific access flow (operator PDF diagram): Access flow includes passport / pre-approved lists / one-time pass, with access via access card and turnstile, and 24/7 security and duty engineers indicated.
- Compliance certifications (facility-specific ISO/SOC/PCI, certificate IDs, audit scope): Operator PDF lists ISO 27001:2013, ISO 9001:2015, and PCI DSS v3.2 (certificate IDs and audit scope are Not publicly disclosed).
- Other operator-listed compliance items (facility PDF): Operator PDF also lists Uptime Institute Accredited Operations Specialist (AOS), FSTEC attestation for personal data protection, and FSB license for cryptography activities (certificate/license IDs and scope are Not publicly disclosed).
🌐 Connectivity & Carrier Access
- Networks present (third-party directory): PeeringDB lists Networks: 25 for “Linxdatacenter (Moscow).”
- Carriers on-net (third-party directory): Not publicly disclosed in the PeeringDB facility record excerpt (carrier roster is not shown in the cited snippet).
- Meet-me room / cross-connect products / pricing (facility-specific): Not publicly disclosed.
- Internet Exchange (IX): PeeringDB lists Local Exchanges: 3 for “Linxdatacenter (Moscow).”
- Operator-stated IX connectivity (operator PDF): Operator PDF states a connection point to MSK-IX.
💼 Who It Serves
- Organizations seeking colocation at the Moscow facility published by Linx at ul. 8 Marta, 14, str. 1 (Moscow).
- Network participants interconnecting at the site where PeeringDB lists 25 networks present and 3 local exchanges.
- Customers requiring operator-stated infrastructure characteristics for the Moscow site (e.g., 5 MW design power, 2N/UPS redundancy, N+1/2N cooling, Novec 1230 suppression) as published in the Linx Moscow technical PDF.