Edged: BIL02 Bilbao-Arasur Data Center
About BIL02 Bilbao-Arasur Data Center
The BIL02 Bilbao-Arasur Data Center is operated by Edged Energy in strategic partnership with MERLIN Properties. It is part of the Bilbao-Arasur hyperscale campus located in the Arasur industrial and logistics hub, just south of Bilbao in Northern Spain.
Its location offers significant market advantages: proximity to major European infrastructures, presence at a high-speed fiber crossroads, low-latency connectivity between Northern Europe, Spain, and undersea cable systems linking to other continents, and access to sustainable energy resources.
BIL02 is part of a campus designed for modern demands—including AI, cloud services, and high-performance computing—while emphasizing sustainability and efficiency.
⚙️ Facility Highlights
- Critical Power Capacity: BIL02 offers ~48 MW of critical IT power.
- Campus Power Size: The full Bilbao-Arasur campus totals ~118 MW critical capacity across its buildings.
- Design & Redundancy:
- Tier III design with concurrently maintainable infrastructure.
- N+1 redundancy for power, UPS, and cooling systems.
- Cooling Technology:
- “Waterless cooling” is used—i.e. zero liters of water used per kWh for cooling.
- Modular cooling via ThermalWorks systems, which are designed for ultra-high density racks.
- Support for high rack densities: up to ~70 kW per rack via air cooling, and up to ~200 kW with liquid cooling.
- Energy Efficiency: Guaranteed PUE of 1.15.
- Clean Energy & Sustainability:
- 100% renewable energy via solar/wind PPAs, adjacent solar farm.
- Operationally carbon neutral design commitments.
🔐 Security & Compliance
- Physical Security: 24×7×365 access controls; secure site fencing; multiple layers of access controls.
- Fire & Smoke Systems: Addressable smoke detectors; hot-aisle early detection; double interlock pre-action fire suppression in data halls.
- Power and Mechanical System Reliability: Battery backup across all electrical/mechanical systems; standby generation using low emissions (Tier IV Final) engines.
- Certifications & Standards: Designed to Tier III concurrently maintainable; guaranteed uptime SLAs; compliance to environmental and efficiency standards. Specific third-party certifications aren’t listed for BIL02 (public sources do not yet list e.g. Uptime Institute certification or ISO details).
🌐 Connectivity & Carrier Access
- Carrier-Neutral Facility: Multiple fiber providers; diverse fiber entry points into the campus.
- Fiber Crossroads Location: Positioned at a junction of high-speed fiber networks with ultra-low latency links to Northern Europe and trans-oceanic/undersea systems.
- Interconnection Options: Meet-me rooms in BIL02; connections among campus buildings and external networks.
💼 Who It Serves
- Large enterprises, hyperscalers, and cloud providers needing high power, high density, and scalable infrastructure.
- Organizations with workloads in AI, machine learning, HPC, large data analytics that demand both performance and low latency.
- Customers prioritizing sustainability, environmental impact, renewable energy, and efficient cooling technologies.
- Telecom / carriers looking for interconnection and fiber network endpoints due to its location at fiber crossroads.